For Nucor Steel West Virginia commissioning support and Heraeus internal coordination. This page is not listed in the site navigation and is excluded from site search.
IM2 / SensorLab Steel Related
Documents and Help Files
-
Simple guide save the settings from an SLS/iM2 unit:
Quick field procedure for logging into SensorLab (SLS/iM2), accessing the active program, and exporting the settings file to a USB drive for backup or transfer.
SLS - Save Settings File to USB Memory Stick.pdf -
Heraeus IM2 SensorLab to Receiver Box Wiring Guide:
Wiring guide for connecting Heraeus IM2 SensorLab to the Receiver Box using CAT5/6 and DB9–RJ45 adapters: clarifies
that RJ45 pin 7 must map to DB9 pin 9 (not pin 4) to complete the 24 V DC return path, and includes male/female
DB9 diagrams for correct terminations.
Heraeus IM2 SensorLab to Receiver Box Wiring Guide.pdf -
Disable QUBE Wireless Sleep Mode on SLS:
Step-by-step guide to disable QUBE Wireless sleep on SensorLab Steel (SLS)—includes the exact menu path
(login 2448 → Settings → Configure → Basic Instrument Setup → Dual Station Setup), which option to check for
“Wireless via Wireless 1,” and how to save and activate the new program..
Disable QUBE Wireless Sleep Mode on SLS.pdf -
Disable QUBE Wireless Safety on SLS:
Quick steps to disable QUBE Wireless Safety on SensorLab Steel (SLS): navigate to Settings → Wireless Safety,
uncheck “Wireless safety mode enabled,” then Save and commit program changes—includes annotated screenshots..
Disable QUBE Wireless Safety on SLS.pdf -
Set SLS To Display Time Interval Between Measurements:
Directions for setting up the SLS to display the time interval between samples on the screen.
Quick steps to show the time interval between measurements on SLS:
log in (password 2448), open User Settings → Display settings → Edit, check “Display interval between measurements,” and Save.
Note: this isn’t stored in the Settings File backup.
Set SLS To Display Time Interval Between Measurements.pdf -
IM2/SensorLab Celox BathLevel EMF — Licensing Procedure (PDF):
Step-by-step guide to request and apply a BathLevel EMF license on SensorLab/IM2: generate
and save the Hardware ID (.txt), email it to Heraeus, then load the returned license file from
USB via System Tools → License → Update until you see “The license is active.”.
SLS Celox Bath Level Licensing Procedure.pdf -
SLS Remote Viewer Installation:
Directions for installing the SLS Remote Viewer.
Remote Viewer setup for IM2/SensorLab Steel: download and unzip SensorLab_v3.3.0, run DeployAgent.exe,
apply the henmachine.reg license key, then connect (scan or by IP) over LAN—supports up to 4 remote PCs on Windows 7+.
SLS - Installing Remote Viewer.pdf -
iM2SensorLab SensorLabSteel SensorLabMultilance 8.3.1 Manual:
IM2/SLS Manual .
iM2SensorLab_SensorLabSteel_SensorLabMultilance_8_3_1_EN_original.pdf
IM2/SLS ProfiNet Comms Related
-
Set up SLS for ProfiNet Output Registers:
Directions for enabling the ProfiNet module and seting it up to used Output registers up the SLS .
Set up SLS for ProfiNet Output Registers.pdf -
SLS ProfiNet Output Register Direct Overlay (TIA Portal v18) – Rev1 Quick Setup Guide:
Step-by-step instructions for setting up a direct UDT overlay of the SLS ProfiNet output register data in TIA Portal v18.
Covers importing the UDT_HEN_SLS2PLC_Overlay source file, generating the PLC data type from source, locating and recording the input
start address in Device configuration → Device overview, creating an EAF_SLS PLC tag table, adding Station 1 / Station 2 tags at the correct
%I addresses, then compiling, downloading, going online, and monitoring live data from the expanded UDT tags.
SLS ProfiNet Output Register Direct Overlay_Rev1.pdf
UDT_HEN_SLS2PLC_Overlay.zip
UDT_HEN_PLC2SLS_Overlay.zip -
SLS Output Register Memory Organization Reference for ProfiNet :
Illustration mapping Output register data from the SLS internalling using TIA Portal .
SLS Output Register Memory Organization Reference- PNet.pdf -
Siemens Step 7 iM2/SLS Beckhoff ProfiNet Configuration:
Step-by-step guide for connecting a Heraeus iM2 / SensorLab Steel (SLS) to a Siemens PLC over ProfiNet using the Beckhoff EL6631.
Covers SLS-side telegram setup, High Byte First result formatting for Siemens, GSD installation in Step 7, adding the EL6631 and
100 WORD I/O module, setting addresses, downloading hardware config, and monitoring live data in a variable table.
iM2_SLS Beckhoff Profinet Configuration Step 7.pdf
Hydris / HydroVAS Related
Documents and Help Files
### Hydris PLC Integration (AOIs / Siemens FCs / Telegrams)
-
Hydris_Siemens_TIA_Portal_Integration_v1:
Step-by-step integration guide for Siemens TIA Portal (v18) using the FC_HEN_HydrisParser_Hyd2PLC parser.
Covers source import, UDT generation, overlay tag mapping, Data Block structure, ladder call implementation, and live monitoring of parsed and derived values.
Includes configuration notes for byte-aligned telegrams, byte order requirements, and correct input address mapping.
Hydris Siemens Tia Portal Integration v1.pdf -
HEN_HydrisParser_Hyd2PLC_Siemens_FC:
Siemens TIA Portal SCL function (FC) and supporting UDTs for parsing Hydris/HydroVAS data using PLC-aligned output telegrams.
Designed for direct overlay of the Hydris input image into a structured UDT with clean parsed values and derived BOOLs for automation logic.
Includes FC_HEN_HydrisParser_Hyd2PLC.scl and associated UDT definitions for Parsed and Derived result structures.
HEN_Hydris_Siemens_FC_v1_0.zip -
Hydris_Industrial_Output_Telegrams_PLCAligned_v1_High_Byte_and_Low_Byte:
Hydris industrial output telegram package containing both PLC-aligned variants of the “Industrial Output Telegram PLCAligned v1” definitions:
High Byte v1 and Low Byte v1. These Hydris→PLC telegrams preserve the same field structure and byte offsets while providing either big-endian or
little-endian multibyte formatting, reordered for clean PLC-side 4-byte alignment and easier direct overlay into controller data structures with minimal parsing workarounds.
Hydris Industrial Output Telegrams PLCAligned v1 - High Byte and Low Byte - 04022026.zipGM_Hydris_PLC_Aligned_Output_Telegrams_Reference:
Reference guide describing the Hydris PLC-aligned industrial output telegrams and how they differ from the default Hydris output telegram documented in the manual.
Includes the purpose of the new High Byte and Low Byte variants, the rationale for the PLC-aligned layout, a comparison to default Table 26 offsets, and the equivalent
offset table for the new telegram definitions.
GM_Hydris_PLC_Aligned_Output_Telegrams_Reference - 04022026.pdf
CasTemp / CasTip Related
CTW E5
-
E5_Castemp_Telegram_10.pdf:
Field-by-field reference for CasTemp Wireless E5 Superheat Output Telegram #10: lists each element
(e.g., MODID, BAT, DATETIME, TMP, SH, TL, PRSH, ROC, ERR/ERRLIST, RSSI, HN, GN), data types and lengths,
byte order (high-byte first for floats/time), plus complete sample frames in ASCII and HEX with total byte
counts for PLC parsing.
E5_Castemp_Telegram_10.pdf -
CTW E5 EIP Comms Configuration and EDS Installation Rev1:
Step-by-step setup for CasTemp Wireless E5 on EtherNet/IP in Studio 5000, including installing the Anybus CompactCom 40 EDS via the
EIP Hardware Installation Tool, creating the module, setting 128-byte Input / 64-byte Output (SINT) assemblies, and noting key tags like CTWE5:I.Data
and ConnectionFaulted.:
CTW E5 EIP Comms Configuration and EDS Installation Rev1.pdf
---
CoreTemp / OOD Related
Documents and Help Files
-
CoreTemp Level-2 Telegram UDTs (TIA Portal) — Setup & Usage:
This document provides detailed instructions for the import of two ready-made .udt source files into
TIA Portal v18 and map them as structured tags directly over the CoreTemp Level-2 input/output telegram ranges,
then monitor and use the fields in logic.
CoreTemp Level-2 Telegram UDTs (TIA Portal) — Setup & Usage -
CoreTemp Level-2 Telegram UDTs (TIA Portal) — Setup & Usage Video:
Video illustrating the procedure described in the "CoreTemp Level-2 Telegram UDTs (TIA Portal) — Setup & Usage WIP1.pdf"
CoreTemp Level-2 Telegram UDTs (TIA Portal) — Setup & Usage Video
CoreTemp Add-Ons FBs and UDTs
-
HEN CoreTemp Siemens UDTs:
This Zip file Includes a set of PLC data types that implement a 1:1 memory image of the Level-2 industrial telegrams described in
the CoreTemp manual (Input telegram = data sent from PLC to CoreTemp; Output telegram = data sent from CoreTemp to PLC).
EDS/GSDML Related
Siemens
-
Anybus CompactCom PROFINET M30 module File GSDML-V2.25-E4_V703-ABCC-PRT2P-20140910.xml:
The Anybus ABCC-PRT (2-Port) CompactCom PROFINET M30 module File GSDML-V2.25-E4_V703-ABCC-PRT2P-20140910.xml for ProfiNet communication..
- Instruments:
- DTE E4
- Celox E4
- AlZin-Lab E4
-
Anybus CompactCom PROFINET M40 module File gsdml-v2.33-heraeus-abcc40-pir-20180907.xml:
The Anybus ABCC40-PIR CompactCom PROFINET M40 module File gsdml-v2.33-heraeus-abcc40-pir-20180907.xml for ProfiNet communication..
- Instruments:
- CoreTemp
- Hydris/HydroVAS
- CasTemp E5
- DTE E5
-
Beckhoff EL6631 GSDML for IM²/SensorLab Steel (GSDML-V2.33-beckhoff-EL6631-20200116.xml.zip):
Beckhoff EL6631 GSDML for Siemens Step 7 (ProfiNet):
GSDML file package for installing the Beckhoff EL6631 ProfiNet device description into Siemens Step 7 hardware configuration.
Use this file to create the EL6631 hardware image, add the ProfiNet IO device to the PLC project, and map the required
100 WORD input/output module for Heraeus iM2 / SensorLab Steel (SLS) communications..
- Instruments:
- IM²/SensorLab Steel